SELF LIMITING CABLE – Normal Temperature 25 W/M

Regulating Tracer suited for Frost protection & process temperature maintenance

 

  • Approved for use in and hazardous areas
  • Available factory terminated and in continuous lengths on drums
  • Frost protection or process temperature maintenance to metallic and nonmetallic piping, tanks & equipment.

 

The self-limiting heating cable is used for frost protection or process temperature maintenance to metallic and nonmetallic piping, tanks & equipment.

The cables derives its Thermotraceself-regulating Tracer characteristic from the inherent properties of the semi conductive core material.

With increase and decrease in cable core material temperature, conductive paths decrease and increase and result in heat output decreasing or increasing.

This occurs at every point along the cable’s length, adjusting the power output to the varying conditions.

As the cable self-regulates its heat output, it limits the maximum sheath temperature, thus making it burn-out proof

Available factory terminated and as in continuous lengths on drums.

 

APPLICATION

  • Tanks
  • Valves
  • Pumps

 

CONSTRUCTION

  1. Bus Bar: Coated Copper, Nom. 1.25 sq.mm
  2. Heating Core: Semi conductive matrix
  3. Insulation: Modified Polyolefin
  4. Metal Sheathing: Coated Copper Braiding / Aluminum Mylar and earth drain wire
  5. Outer Sheath: Modified polyolefin/Fluoropolymer

 

RANGE

  • Aluminum Mylar with drain wire + Modified polyolefin
  • Braiding + Modified Polyolefin
  • Braiding+Fluoropolymer
  • Rated Output: 10 W/m, 15 W/m, 20 W/m 25 W/m & 33 W/m

 

TERMINATED STANDARD LENGTHS:

  • 5, 8, 10, 12, 15, 20, 25, 30, 35, 40, 50, 60 & 70 m

 

SPECIFICATIONS

  • Standard Power output at 10°C on Pipe – 10, 15, 20, 25 & 33 W/m
  • Voltage Supply – 230V a.c
  • Min. Installation Temperature – -65°C
  • Operating Temperature – Switched on – Max 65°C
  • Operating Temperature – Switched off – Max 85°C
  • Minimum Bending Radius – 25mm
  • Qualification – IS/ EN/ IEC 60079-30-1 and ATEX – UV Protection, REACH & ROHS

25 W/M

SELF LIMITING CABLE – Normal Temperature 25 W/M

Datasheet

Send an inquiry

We consistently strive to develop serious and long-term cooperative relationships with our partners and suppliers.

Contact us

Are you interested in a collaboration?

We consistently strive to develop & build serious and long-term cooperative partnerships with our partners and suppliers.

Call me
Download
E-catalogue